You are here:

Load Bank for Data Centers

Load Bank for Data Centers
With the in-depth development of informatization , the combination of Internet and data center is gradually integrated into our production and life,the data center is a mailing combination of sites tools, processes, etc., where personal and enterprise information and data resources are centralized, integrated, shared, and analyzed. The convergence of language and data makes equipment reliability even more important, In order to ensure the stability and safety of network and data power consumption, the equipment load banks of the key departments, such as financial settlement center, data center, disaster recovery center and important system dispatching center are used for daily load detection of backup power supply, It is necessary equipment for the loading capacity and daily maintenance of diesel generator sets, AC stabilized power supply, inverter and high-power UPS of financial and data center systems. Therefore, we have developed a data center load bank solution to respond to the growing demand for removable load bank at sites with multiple generators in the data center.
Description

Product specification:

Power range:100KW-6MVA 
Voltage range: AC1000V/AC3.3KV/AC6.6KV/AC10.5KV/AC13KV/AC20KV
Power factor:PF:0.8-1.0
Frequency:50Hz-60Hz
Level of protection:IP55


Load bank including: 

resistive load, inductive load, resistive/ inductive load 


Performance advantages and characteristics:
Excellent safety, reliable stability, flexible control method.
Directly testing of high voltage units, usually 10.5KV high voltage units.
Reliable insulation, pressure resistance, high temperature resistance, anti-corrosion, moisture-proof, rain-proof, can run stably in outdoor humid environment without transformer relay, which saves investment and improves accuracy.
With comprehensive protection function,  it can automatically stop working under dangerous conditions such as over-current, over-heat, abnormal fan, protect itself and the unit, avoid accidents.
High safety, resistance safety distance is 120 times of the national standard) .
It has the functions of steady state test, setting test, wave test, sudden loading and unloading test, harmonic recording analysis and so on.
Simple operation, easy installation, multi-steps design, response speed is less than 1ms, It can realize whole-process unmanned intelligent detection. The open software system has strong compatibility and can be converted into curves and other forms, and the test results can be printed automatically.
Applied to finance, insurance, communications, industrial parks, education and other fields.